Availability: | |
---|---|
Quantity: | |
160XFW001
Windouble
Main Parameters
Model | 160XZW001 |
Pole Pairs | 1 |
Input Voltage | AC 7 Vrms |
Input Frequency | 10000 Hz |
Transformation Ratio | 0.5 ±10% |
Accuracy | ±10' max |
Phase Shift | 28.8° ±3° |
Input Impedance | (150 ±23) Ω |
Output Impedance | (980 ±147) Ω |
Dielectric Strength | AC 500 Vrms 1min |
Insulation Resistance | 250 MΩ min |
Maximum Rotational Speed | 20000 rpm |
Operating Temperature Range | -55℃ to +155℃ |
Guide to Resolver Installation
A resolver is a specialized transformer that provides stable voltage and current output during rotation. Proper installation is crucial for its performance and longevity.
Hanging Installation
Ideal for stationary equipment.
Steps:
Lift the resolver with a suitable rope above the installation point.
Secure it in place with mounting screws tightened using a wrench.
Connect input and output cables ensuring correct and secure wiring.
Verify secure installation and perform a test.
Bracket Installation
Suitable for mobile equipment requiring frequent movement.
Steps:
Attach the resolver to scaffolding or brackets at the installation site.
Position correctly and tighten mounting screws with a wrench.
Connect cables for input and output.
Conduct a test post-installation.
Safety and Testing
Ensure accurate positioning and firm screws to prevent equipment failure during movement.
Choose the installation method based on the equipment's mobility needs.
Prioritize safety during operation and perform comprehensive tests to guarantee normal functioning.
Main Parameters
Model | 160XZW001 |
Pole Pairs | 1 |
Input Voltage | AC 7 Vrms |
Input Frequency | 10000 Hz |
Transformation Ratio | 0.5 ±10% |
Accuracy | ±10' max |
Phase Shift | 28.8° ±3° |
Input Impedance | (150 ±23) Ω |
Output Impedance | (980 ±147) Ω |
Dielectric Strength | AC 500 Vrms 1min |
Insulation Resistance | 250 MΩ min |
Maximum Rotational Speed | 20000 rpm |
Operating Temperature Range | -55℃ to +155℃ |
Guide to Resolver Installation
A resolver is a specialized transformer that provides stable voltage and current output during rotation. Proper installation is crucial for its performance and longevity.
Hanging Installation
Ideal for stationary equipment.
Steps:
Lift the resolver with a suitable rope above the installation point.
Secure it in place with mounting screws tightened using a wrench.
Connect input and output cables ensuring correct and secure wiring.
Verify secure installation and perform a test.
Bracket Installation
Suitable for mobile equipment requiring frequent movement.
Steps:
Attach the resolver to scaffolding or brackets at the installation site.
Position correctly and tighten mounting screws with a wrench.
Connect cables for input and output.
Conduct a test post-installation.
Safety and Testing
Ensure accurate positioning and firm screws to prevent equipment failure during movement.
Choose the installation method based on the equipment's mobility needs.
Prioritize safety during operation and perform comprehensive tests to guarantee normal functioning.