Multipole Motor VR Resolver Size 74 Series
You are here: Home » Products » Variable Reluctance Resolver » Multipole Motor VR Resolver Size 74 Series

Product Category

Contact Us

loading

Multipole Motor VR Resolver Size 74 Series

Lead length, wiring harness and rotor's inner diameter can be customized.
Outline and installation dimension drawing is available by inquiry.
Custom solutions can be technically supported by our engineers.
Availability:
Quantity:
facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
sharethis sharing button
  • J74XU9735

  • Windouble

Main Parameters


Model J74XU9732B J74XU9733 J74XU9734A-L5 J74XU9735C J74XU9736A
Pole Pairs 2 3 4 5 6
Input Voltage AC 7 Vrms AC 7 Vrms AC 7 Vrms AC 7 Vrms AC 7 Vrms
Input Frequency 10000 Hz 10000 Hz 10000 Hz 10000 Hz 10000 Hz
Transformation Ratio 0.286 ±10% 0.286 ±10% 0.286 ±10% 0.286 ±10% 0.286 ±10%
Accuracy ≤ ±60' ≤ ±40' ≤ ±30' ≤ ±25' ≤ ±20'
Phase Shift ≤ ±15° ≤ ±15° ≤ ±15° ≤ ±15° ≤ ±15°
Dielectric Strength AC 500 Vrms 1sec
Insulation Resistance 250 MΩ min
Rotor Inner Diameter 12.7 mm 12.7 mm 12.7 mm 18 mm 18 mm
Wire Cross Sectional Area 0.35 mm² 0.35 mm² 0.35 mm² 0.35 mm² 0.35 mm²
Maximum Rotational Speed 30000 rpm 30000 rpm 30000 rpm 30000 rpm 30000 rpm
Operating Temperature Range -40℃ to +155℃


Working Principle

The Variable reluctance resolver operates based on the magnetoresistive effect and consist of two main components: a rotating part with a round magnet and a non-rotating part with magnets and coils. The energized signal from the coils generates a magnetic field that induces a magnetoresistive effect on the stationary magnets, allowing the rotating part to sense and output signals.


Differences with Common Resolvers

Signal Transmission: Common resolvers transmit signals through the main and secondary circuits, often using wound wires. In contrast, variable reluctance resolvers rely on the magnetoresistive effect and do not require winding for signal transmission.


Structure: The physical construction and internal components of the two types of resolvers differ, impacting their performance and suitability for specific applications.


Application Scenarios: Common resolvers are typically used in low-voltage applications, such as electrical engineering for small switches or low-power motors. Variable reluctance resolvers are favored for high-precision applications, including precision instruments and control equipment such as the eletric vehicle motor.


Advantages

High precision suitable for critical control systems.

Robust design for applications requiring durability and reliability.